Multi-stage High Power and Temperature Difference TEC Module

Beijing Huimao cooling equipment Co.,Ltd technology has made the two-stage high power and high temperature difference Thermoelectric Cooling Module. Its power enables to reach tens of watts and its temperature difference is over 90.We can supply this kind of module in large quantities. Its coming into the world will welcome in a new generation of electric cooling refrigerator, and it brings possibility of the electrical cooling air cooler.   

Model

Couples

Umax

(V)

Imax

(A)

ΔT

(C)

Qmax

(W)

L×W×Hmm

R

(Ω )

 

TEC2-03103T125 

31 

3.5 

3

75 

 

20×15×9.0 

-

 

TEC2-10204T125

102

8.6

4.5

87

12.8

Top:20x20/Base:30x30

 

 

TEC2-10206T125

6.0

87

 

TEC2-25405T125  

254

15.2

5

90

 

40×40×8.10

2.45  

 

TEC2-25406T125

6

90

 

40×40×7.20

2.20

TEC2-25407T125

7

100

 

40x40x7.50

 

TEC2-25408T125

8

100

 

40×40×8.10

1.60

 

TEC2-25409T125

9

100

 

40×40×9.90

1.50

 

TEC2-25410T125

10

100

 

40×40×7.90

1.30

 

TEC3-09105T125

91

7.3

4.5

90

 

 

 

 

TEC3-11903T125

119

7.7

3.5

95

6.5

Top:15x15,Middle:20x20,Base:30x30

 

 

TEC3-11904T125

4.0

95

 

TEC3-22902T125

229

15.2

2

100

 

40×40×8.25

6.40

 

TEC3-22903T125

3

 

40×40×10.80

4.50

 

TEC3-22904T125

4

 

40×40×9.40

3.10

 

TEC3-22905T125

5

 

40×40×9.00

2.80

 

TEC3-22906T125

6

 

40×40×8.80

2.20

 

TEC3-22907T125

7

 

40×40×8.40

1.95

 

TES4-24601T125

246

15.2

1.3

100

 

40×40×10.0 

10.5

Two-stage Thermoelectric Cooling Module Structure

 

 

Relationship between Operating Voltage and Temperature Difference of TEC2-25407T125(Under the heat sink on hot-side with thermal resistance 0.3/W and the ambient temperature 20 )

 

Relationship between Temperature and Cooling Power (Under the heat sink on hot-side with thermal resistance 0.3/W and the ambient temperature 20 )

 

 

back to the main page